Pyralux AC182500: Single-Sided Stackup and Termination

Pyralux AC182500 is a single-sided adhesiveless flex construction. The current AC ordering table distinguishes 18 繕m ED or RA foil variants over a 25 繕m dielectric. Its practical selection often turns on contact fit, local reinforcement and the complete installed thickness rather than the base laminate alone.

Exposed contacts at the ends of flexible circuit tails
Exposed contacts at the ends of flexible circuit tails. 勛圖tv site archive image; illustrative context, not a current inspection or ownership record.

Make sidedness explicit

One copper face is supplied. Protective film, a shield bonded later or a stiffener must be identified separately. A two-layer finished flex requires an appropriate second conductor construction; it does not follow from adding coverlay. Keep the circuit-layer count distinct from the number of physical material layers in the section.

Pyralux AC182500: distinguish the physical layers
Pyralux AC182500: distinguish the physical layers. Original explanatory diagram; conceptual, not a released circuit or inspection record.

Construction and decision boundaries

Review itemWhat this page establishesWhat remains project-specific
ArchitectureSingle-sided ACCoverlay does not add a circuit layer.
Critical regionConnector tail with local reinforcementMeasure at the required location.
ToleranceNominal and positive deviationsArithmetic interval, not process capability.

Build the connector-region stack

Enter every physical layer at the connector tail in the thickness worksheet. Include copper, dielectric, coverlay where present, adhesive, stiffener and any finish contribution significant to the requirement. Do not use the bend-span thickness for the mating-contact region. Compare the resulting interval with the connector manufacturer's drawing, including its measurement location and tolerance convention.

Review itemWhat to establish
Supplied formOne copper face and complete suffix
FitConnector-region layer stack and limits
RegistrationContacts, coverlay and stiffener datum
LimitArithmetic sum is not a connector-fit approval

Stackup thickness interval sum

勛圖tv ENGINEERING

Stackup thickness interval sum

Flexible Material Engineering
Loading Stackup thickness interval sum…
Using this tool & sharing results

Use the stated units, input limits and model assumptions. Results support an engineering discussion; they do not approve a design, process or production order.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Use the current inputs and keep the assumptions

Start with the example only to inspect the units and the calculation boundary. Replace every assumption with a value tied to your own document or measurement. An empty numeric field is not zero. The review-reference field is a local label; avoid entering customer names, confidential part numbers or other private information into a public worksheet.

After calculating, read the notes alongside the numerical result. Changing any input invalidates the displayed result and disables its download until you calculate again. For a comparison, keep the units, geometry, material condition and measurement boundary consistent. A long decimal result does not imply equally precise input data. The downloadable record stays on your device and can be attached manually to an inquiry. It is not automatically transferred into the Contact form.

If an input is unknown, identify the person or document needed to resolve it. Do not fill a gap with a favorable generic value simply to obtain a result. You can request a material or fabrication review without using the tool. The arithmetic illustrates a relationship; it does not accept a construction, certify a material, establish current pricing or replace a supplier process specification.

InputWhat to establish before using it
Review referenceNonconfidential revision label.
Layer entries 繚 CSVAll dimensions in mm. Use each physical thickness once. Minus and Plus are positive absolute deviations, not percentages.

Optional cost comparison from your own allowances

Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a 勛圖tv quotation. You can contact the team without completing it.

勛圖tv ENGINEERING

Optional project allowance comparison

Flexible Material Engineering
Loading Optional project allowance comparison…
Using this tool & sharing results

Budget outputs are planning scenarios. Check the included costs and rate assumptions; a confirmed quotation requires a review of your files and scope.

After changing inputs, update the result before using it. Where a download or copy action is available, review that brief and attach or paste it into your enquiry. Opening Contact does not transfer these inputs or send a request.

How to use and share tool results

Compare a thinner base honestly

AC181200 may change handling and the bend section, but the connector tail may still need reinforcement. A nominal laminate reduction does not always reduce the installed assembly thickness. Conversely, an unnecessarily thick stiffener can erase the intended benefit. Ask whether the design constraint is local insertion fit, global packaging or bending motion before making the change.

Populated flexible circuit with attached connectors
Populated flexible circuit with attached connectors. 勛圖tv site archive image; illustrative context, not a current inspection or ownership record.

Keep adhesive alternatives separate

An LF9110R construction introduces a cured adhesive layer and different starting copper. AP8525R is double-sided. Neither should appear as an equivalent merely because all are polyimide-based. A comparison needs the same final conductor geometry, electrical tests, interface and manufacturing scope.

Pyralux AC182500: worksheet boundary
Pyralux AC182500: worksheet boundary. Original explanatory diagram; conceptual, not a released circuit or inspection record.

Control termination and coverlay details

State the contact geometry and which surface faces the connector. Show the coverlay setback, stiffener boundary and allowed positional error relative to the contacts. Consider how the tail is handled before insertion and whether the assembly process can damage an unsupported edge. Registration should be inspected at the feature that the connector actually engages.

Quote the usable assembly

Provide the connector part drawing, complete foil suffix, contact finish, panel delivery format and quantity. Ask for separate treatment of initial tooling and recurring production. The layer-sum tool gives a transparent dimensional starting point, while the manufacturing proposal must resolve local compression, process tolerances and the agreed inspection method.

Reconcile the connector tail and the flexible span separately

Reconcile the connector tail and the flexible span separately
Review pointInput to recordDecision or verification
Contact regionList the layers present exactly where the connector gauges thickness.Coverlay outside the contact area must not be counted as though it sits under the contact.
Stiffener datumDimension the stiffener edge from a stable contact datum.Check insertion depth and latch engagement after positional tolerances are included.
AlternativeCompare a thinner base with a local stiffener against a thicker base throughout.Evaluate fit and bend geometry separately rather than choosing the lowest nominal total.

Use the review points above alongside the worked example on this page. Record the chosen inputs with the drawing revision and send unresolved items with the enquiry. A supplier response should identify the proposed construction and the evidence needed for release.

Pyralux AC182500: review sequence
Pyralux AC182500: review sequence. Original explanatory diagram; conceptual, not a released circuit or inspection record.

Standards, source context and limits

Use the edition, amendment and material-document revision named in the purchase agreement. A standards title, marketing label or supplier product family does not establish that a particular lot meets a requirement. Public summaries are useful for scope; the controlled specification and applicable test method govern acceptance.

The examples on this page are illustrative engineering scenarios. They are not 勛圖tv production records or guaranteed material values. Source links identify the organizations responsible for the referenced information. Confirm applicability to the exact grade, construction and test condition before carrying a number into a drawing or qualification report. For a flex board, distinguish the design requirements in IPC-2223, finished-board qualification and performance in IPC-6013, and the material scopes of IPC-4202, IPC-4203 and IPC-4204. These cover different deliverables; naming them does not certify the material or factory. State the contracted revision and applicable material sheet. Source review date: 3 October 2026. Legacy designation, present availability and an approved replacement are separate questions.

Pyralux AC182500: inquiry handoff
Pyralux AC182500: inquiry handoff. Original explanatory diagram; conceptual, not a released circuit or inspection record.

For fabrication scope and the agreed construction requirements, see PCB manufacturing.