勛圖tv 繚 ENGINEERING GUIDE
Isola Tachyon 100G PCB: Channel Loss and Copper Options
Isola Tachyon 100G is a low-loss laminate and prepreg system intended for demanding digital interconnects. The useful engineering question is whether a specific copper and dielectric construction can meet the channel budget. The product name is not a guarantee that every board supports a particular data rate.
This page follows the route from source-qualified electrical data to a complete loss allocation. The Isola material overview remains the broader selection entry point.

Keep the current source revision with the electrical model
The official product page lists a typical Dk of 3.02 at 10 GHz and Df of 0.0021, with separate test-method context. Its revision history records a Df method correction in March 2026. A downloaded older PDF and the current page may therefore have different documentation details.
Use one controlled source revision in the design record. Do not average conflicting tables or retain the most favorable value from each. If the material model came from a supplier simulation file, record its construction and extraction basis alongside the published characterization.
Evidence and construction decision
| Item | Source or model boundary | Action for the design review |
|---|---|---|
| Identity | Tachyon 100G with exact copper option | A name is not a data-rate guarantee. |
| Headline data | Dk 3.02 / Df 0.0021 at 10 GHz | Use construction-specific inputs for design. |
| Revision | March 2026 Df-method correction | Do not merge old and new method labels. |
Specify copper and glass instead of only naming the resin
The product information includes smooth-copper options and spread-glass constructions. Those choices matter to the electrical proposal. A quote that changes the foil profile or dielectric construction can change the complete line loss even while retaining Tachyon 100G in the material field.
State copper type, finished thickness, glass construction and critical dielectric intervals. Ask for proposed changes before routing dimensions are frozen. Spread glass may help address local dielectric variation, but it is not a substitute for evaluating the actual differential-pair geometry and timing requirements.
| Review item | What to establish |
|---|---|
| Construction | Tachyon 100G copper, glass and dielectric intervals. |
| Revision control | Record electrical method and source revision. |
| Channel boundary | One frequency and consistent reference planes. |
| Model limit | Loss allocation is not interface compliance. |
Allocate a channel budget at one defined frequency
The tool subtracts fixed discontinuity allowance and reserved margin from a user-entered total loss budget. It then compares the remaining allocation with complete routing attenuation per unit length. The example uses 20 dB total, 5 dB fixed, 3 dB margin and 1 dB/in routing loss; a 10 inch route leaves 2 dB.
All figures are hypothetical and must share a frequency and reference-plane definition. The model does not sum a material Df directly into channel loss. It also does not validate return loss, crosstalk, equalization or an interface compliance mask.

Channel loss budget at one frequency
Channel loss budget at one frequency
Use the current inputs and keep the assumptions
Start with the example only to inspect the units and the calculation boundary. Replace every assumption with a value tied to your own document or measurement. An empty numeric field is not zero. The review-reference field is a local label; avoid entering customer names, confidential part numbers or other private information into a public worksheet.
After calculating, read the notes alongside the numerical result. Changing any input invalidates the displayed result and disables its download until you calculate again. For a comparison, keep the units, geometry, material condition and measurement boundary consistent. A long decimal result does not imply equally precise input data. The downloadable record stays on your device and can be attached manually to an inquiry. It is not automatically transferred into the Contact form.
If an input is unknown, identify the person or document needed to resolve it. Do not fill a gap with a favorable generic value simply to obtain a result. You can request a material or fabrication review without using the tool. The arithmetic illustrates a relationship; it does not accept a construction, certify a material, establish current pricing or replace a supplier process specification.
| Input | What to establish before using it |
|---|---|
| Review reference | Nonconfidential revision label. |
| Allowed channel loss 繚 dB | Your interface budget at a named frequency and reference planes. |
| Allocated connectors and transitions 繚 dB | Verified or assumed allocation at the same frequency. |
| Reserved engineering margin 繚 dB | Project allocation, not a standard default. |
| Measured or modeled routing loss 繚 dB/in | Complete trace loss for the actual construction, including copper. |
| Routed length 繚 inches | Sum along the agreed uniform routing model. |
Optional cost comparison from your own allowances
Use a quotation or a clearly labeled internal assumption for each input. Keep the quantity, construction and inspection scope the same when comparing alternatives. This uncalibrated planning model adds entered values; it contains no current market rates and does not issue a 勛圖tv quotation. You can contact the team without completing it.
Optional project allowance comparison
Decide whether the board needs a different material or a shorter route
If the routing allocation is insufficient, first inspect the assumed connector, via and package contributions. A premium dielectric cannot remove a severe discontinuity. Shorter routes, better transitions or a different stackup may change the decision more effectively than a material-only substitution.
Compare I-Speed for a matched cost-versus-loss exercise or TerraGreen 400G2 for an exact-suffix low-loss route. Keep the same channel boundary when comparing alternatives, otherwise the numerical difference can be misleading.
Separate RF phase requirements from digital channel requirements
IS 680 owns the RF dielectric-option and phase-planning task. A digital backplane and a resonant RF circuit may both need low loss but use different model and verification methods. Select the relevant evidence rather than assuming one material ranking serves every application.
For procurement, compare the same quantity, copper construction, layer architecture and testing. The optional allowance model has no supplier price database. Include qualification and coupon work explicitly when they are part of the proposed build.
Request a reviewable high-speed stackup
Provide the lane requirements, frequency or channel specification, reference planes, proposed stackup, trace geometry and transition data. Include the exact material and foil requirement, quantity, assembly history and acceptable substitution policy.
A useful reply identifies a construction that can be analyzed and the evidence required before release. It does not promise a data rate from the product name alone. Keep the approved stackup, model revision and electrical verification boundary together for repeat production.
Tie the exact grade to an electrical construction
State the channel reference planes, frequency range, routing length, copper construction, transitions and interface assumptions together. A laminate loss-tangent value is one input to that system. It is not a complete insertion-loss measurement or a guarantee that a data rate will work.
Use comparable measurement or modeling conditions when screening alternatives. Material changes can require geometry changes to preserve impedance, and copper roughness can alter the result independently of the resin system. Keep the proposed stackup and the channel analysis synchronized through fabrication review.
For procurement, identify the properties that are fixed and the alternatives that can be evaluated. Request evidence at the relevant construction and frequency rather than a broad low-loss label. Compare total delivered scope and validation effort alongside material price. A shorter or better-routed channel may change the tradeoff more than replacing a material name alone.
A useful design-data record retains both the material value and the reason it was selected. State whether the value is supplier characterization, a construction-specific design input, a measured coupon extraction or an early assumption. These sources are not interchangeable. Keep frequency, method and specimen information visible when a comparison uses more than one document.
The tool on this page starts empty because a plausible default can otherwise be mistaken for a verified grade profile. Use the example to understand the units, then replace it with project inputs. A result with many decimal places does not imply that the material or routing-loss input is known to that precision.
For a high-speed design, plan how the model will be checked. Reference planes, coupon geometry, fixtures and the acceptance boundary determine what a measurement means. A coupon that characterizes one line construction does not automatically qualify every route or transition on the board.
Keep the commercial comparison aligned with the engineering one. Quantity, copper, layer structure, test deliverables and qualification effort should be comparable. A lower material allowance can be irrelevant if the proposed construction cannot meet the channel requirement, while a premium grade may be unnecessary if the actual route already has sufficient validated margin.
Standards, source context and limits
Use the edition, amendment and material-document revision named in the purchase agreement. A standards title, marketing label or supplier product family does not establish that a particular lot meets a requirement. Public summaries are useful for scope; the controlled specification and applicable test method govern acceptance.
The examples on this page are illustrative engineering scenarios. They are not 勛圖tv production records or guaranteed material values. Source links identify the organizations responsible for the referenced information. Confirm applicability to the exact grade, construction and test condition before carrying a number into a drawing or qualification report. Sources were reviewed on 3 October 2026. A public catalog search is not proof that an unlisted product never existed. Where the exact designation or current technical sheet could not be verified, this page provides a clarification workflow rather than an invented material specification. Current supply, construction availability and qualification remain separate questions.