勛圖tv 繚 ENGINEERING GUIDE
Reflow Profile and Solder Defects: Analyze the Measured Curve
A reflow profile is the measured temperature history of a product location as it passes through the thermal process. An incorrect or poorly understood profile can contribute to solder defects, but not every defect seen after the oven was caused by the oven. Printing, placement, material condition and board geometry remain part of the investigation.
This page provides a small measured-curve analyzer and a method for connecting thermal evidence to a defect hypothesis. It calculates a sampled peak, average segment slopes and time above an entered threshold. It does not generate an oven recipe or declare an assembly qualified.

Start with the material and component requirements
Obtain the exact paste guidance and the restrictions for the board and sensitive components. Distinguish an alloy's solidus/liquidus from the desired process window. A material may begin melting at one temperature while the product process requires a different combination of peak, time and rate to form the intended joints.
Component classification profiles are not automatically production profiles. Record the source and revision of each requirement and where it applies: joint, package body or another location. A numerical limit without that location can lead to a misleading comparison.
Collect a product curve with a credible sensor arrangement
Document thermocouple location, attachment and product identity. Measure the locations that represent relevant thermal extremes and sensitive features. A loose sensor can report air temperature or an attachment artifact rather than the intended joint. A curve's neat shape does not establish a sound measurement.
Use the thermocouple-placement guide to plan coverage. Repeat measurements after changes that can affect the thermal condition, such as loading, fixture, conveyor behavior or construction. Keep the original data rather than only a screenshot with rounded values.
| Review item | What to establish |
|---|---|
| Input | Strictly increasing sample time, Celsius temperature and a sourced threshold. |
| Output | Sampled peak, interpolated time above threshold and segment-average rates. |
| Limits | Sampling, attachment, location and material requirements remain explicit. |
| Closure | Raw data, changed settings, other locations and defect evidence retained. |
Measured reflow-profile summary
Measured reflow-profile summary
Use the current inputs and keep the assumptions
Choose the question you need to answer before entering numbers. Fields begin blank. Select Load example only to explore the model; example inputs are teaching values, not process recommendations or market prices. The example label remains visible after editing. Reset before preparing a record based entirely on your own data.
Use the displayed units and record the source of every input. Dimensions must share a reference and revision; temperature measurements must identify the location and method. An entered threshold or interval is your supplied review condition, not an IPC limit provided by this website. If a value is unknown, keep it open and obtain evidence rather than filling the space with a familiar number.
Read the assumptions alongside the result. A positive geometric margin answers only the stated calculation. It does not establish wetting, joint strength, production capability or compliance. A negative result remains visible so an incompatible assumption is not hidden. Checklist entries are self-reported and do not prove that the supporting documents were inspected.
Changing an input invalidates the displayed result and disables the download until the calculation is repeated. The text record includes inputs, results and limitations. Processing stays in this browser: no CAD data is read, no measurement system is connected and no information is automatically sent to Contact. Download and attach the record manually if it helps your enquiry. You can contact 勛圖tv directly without using a tool.
| Input | What to establish before using it |
|---|---|
| Review reference | Use a nonconfidential revision/reference. |
| Time s, temperature 簞C per line | Strictly increasing times; 2���500 points. Linear interpolation between measured points. |
| Entered liquidus / review threshold 繚 簞C | Exact material source required; example is not a complete process recipe. |
Understand what the analyzer calculates
Enter increasing time/temperature pairs in seconds and degrees Celsius. Between adjacent samples, the tool assumes a straight line. It calculates time strictly above the entered liquidus or review threshold by interpolating crossings. The highest sampled temperature is reported as the sampled peak; an unmeasured peak between samples cannot be recovered.
For points at 0 seconds/200 C, 10 seconds/220 C and 20 seconds/200 C, a 210 C threshold is crossed at 5 and 15 seconds. The calculated time above that threshold is 10 seconds. The heating and cooling segment averages are plus and minus 2 C per second. These are arithmetic examples, not a recommended profile.

Use slopes and thresholds with the right interpretation
An average slope over a long sample interval can hide a short rapid event. A coarse data set can underestimate a peak or shift a crossing. Choose a sampling method appropriate to the process and retain its limitations. The tool does not calculate flux activation, intermetallic growth, component internal temperature or thermal damage.
Do not use a single time-above-liquidus number to characterize the entire profile. Preheat, soak where applicable, peak, cooling and the temperature differences across the product all matter in relation to the materials. The required limits are project- and product-specific.
Connect symptoms to evidence rather than a one-line cure
Insufficient joining can motivate a review of effective heat delivery, but surface condition and deposit geometry can produce similar results. Beading can motivate review of paste behavior and the thermal history, yet aperture and placement evidence may be more decisive. Component movement can involve wetting-force imbalance and geometry as well as temperature.
Use defect triage to preserve these distinctions. Increasing peak or extending time may change several mechanisms simultaneously. Before a trial, define the hypothesis and what measurement would support or contradict it.
Compare a changed profile across all relevant locations
If a cold location moves into the intended window, check whether a hotter location has exceeded another requirement. Compare the complete curves and the applicable limits. The difference between each location's individual peak is not necessarily the maximum instantaneous temperature difference across the board because those peaks may occur at different times.
Check other outcomes such as bridges, residues, component condition and hidden joints. A trial that eliminates one symptom on a few boards is evidence to investigate further, not proof of process capability or lifetime reliability.
Preserve the profile as a controlled record
Store board/assembly revision, material identities, loading condition, machine recipe identifier, sensor map and raw measurements. After approval, define what changes trigger remeasurement. Link any rework or additional thermal operation to the assembly's exposure record.
When asking 勛圖tv to review a profile-related issue, include the original curve, the symptom map and the limit sources. The downloadable tool result can summarize arithmetic, but attach the actual measurement record manually if useful. For equipment drift after a previously stable process, continue to reflow-oven maintenance rather than silently retuning around an unresolved fault.
Make the measurement chain part of the engineering record
Identify the assembly, revision, loading condition, support and measurement locations before comparing temperature traces. The same oven settings can produce different responses on different products. A trace without its location and attachment method is difficult to interpret when the problem concerns a particular joint or temperature-sensitive component.
Choose locations to test the engineering concern. Large thermal masses, shielded regions, small sensitive parts and package interfaces can respond differently. There is no universal number or placement pattern that makes every profile representative. Keep the sensor and attachment effects in mind when deciding what the measurement actually represents.
Retain the sampled data, time basis and any processing applied. Peak, time above a threshold and segment rates answer different questions. Individual sensor peaks may occur at different times, so their spread is not automatically the maximum simultaneous temperature difference across the board.
When a worksheet interpolates between points, its result depends on the sampling interval. It cannot recover an unmeasured transient or correct an attachment error. Use the summary to organize the record and identify a concern, then evaluate it against the actual material guidance and agreed process criteria.
Track previous exposures of the profiling or rework sample. A repeatedly heated assembly can become less representative through material changes or damage. Summing times across separate events is useful bookkeeping, but it is not a fatigue or remaining-life model and does not authorize another operation.
For supplier discussion, provide the raw trace where available, sensor map, relevant material restrictions, known exposure history and the question to resolve. Distinguish an equipment recipe from a measured product profile. A clear measurement record allows the next review to focus on the thermal constraint rather than reconstructing what a screenshot of the oven display might mean.
Standards, source context and limits
Use the references for their stated purpose. A material-vendor application note supports its specified material and conditions; a research paper reports the study it describes. Neither should be converted into a universal setting or a guarantee for a different assembly. Public standard summaries and contents are not complete normative requirements.
Agree the applicable controlled documents, revisions, acceptance basis and exceptions before production. IPC J-STD-001 concerns requirements for soldered assemblies, IPC-A-610 addresses assembly acceptability, and IPC-7711/7721 addresses rework, modification and repair procedures within its scope. Applicability must be established for the contract and task; this page does not certify compliance or reproduce paid acceptance tables.
The photographs are selected from the existing 勛圖tv website archive and illustrate relevant materials or operations. They do not establish current equipment ownership, certification or completion of your project. Original diagrams explain concepts and measurement boundaries; they are not inspection evidence or released manufacturing drawings.